Smart Solution

Small Data Box with a side heat exchanger is the optimal answer to the requirements of modern, small data centres.

Small Data Box is a reliable and modern system designed for building modular server rooms. The solution is characterized by optimal dimensions, versatility and easy expansion.

Study design

Bolted cabinet’s frame allows for a static load of the 19 ”rack up to 1500 kg.

Multipurpose

Smooth tool-free adjustment of 19” mounting profiles. The width can be changed from 19” to 21” with no need to use additional mounting elements. The frame includes holes for mounting accessories and many elements for cabling organization.

Security

The door is equipped with a swing handle and a 5-point locking system. It is possible to use access control with an electronic swing handle or an automatic opening system. Autonomous extinguishing system within the cabinet and heat exchanger.

Performance

Optimization of the cold air flow provided by the cold and hot aisle separation elements at the rack level. A wide range of cooling capacity of the offered heat exchangers.

Z-SERVER cabinets
Side heat exchanger
Monitoring of environmental conditions
Fire detection and extinguishing system
PDU power strips

Presented solution:

Z-Server cabinet, heat exchanger
  • - Cabinet dimensions: 42 U, 800 x 1200 x 2000 mm + plinth 100 mm
  • - Acceptable static load:: 1500 kg
  • - Single-leaf front door with glass, single-leaf solid rear door
  • - Door with access control system, the possibility of remote opening of the cabinet
  • - Smooth and tool-free adjustment of 19” profiles
  • - Easier installation by marking the profiles with U unit numbers
  • - Possibility to change the width from 19 „to 21” without additional mounting elements
  • - Elements separating the zone of hot and cold air
  • - Elements of cabling organization

  • - Side heat exchanger BWC-DX2, outdoor condenser SDX3
  • - 11.2 kW cooling capacity
  • - 5 AC fans
  • - Dimensions: 42 U, 300 x 1200 x 2000 mm + plinth 100 mm
  • - Front and rear single-leaf solid doors with a 5-point lock and a swing handle
PDU power strips, extinguishing system, monitoring of environmental conditions
  • - Power supply: three-phase 400 V, 16 A
  • - Load: 11040 W
  • - Sockets: 21XC13, 3XC19
  • - Functionality: managed with monitoring on input and sockets
  • - Protocols: HTTP(S); SSH; RS-232 (serial); power IQ; SNMP, SMTP, Modbus

  • - Extinguishing agent: NOVEC 1230
  • - Dimensions: 1 U, 19”

  • - Measurements: temperature, humidity, Detection: smoke, no voltage, line flooding, door opening
  • - Signaling: status lamp
  • - Notification: e-mail, SMS

Air conditioning system

Our team of specialists, on the basis of the submitted specifications of the installed devices, selects the optimal cooling system, which guarantees the cooling performance corresponding to the actual needs of the customer.

Advantages of side heat exchangers

  • Even distribution of cold air over the entire height of the exchanger.
  • Optimal adjustment of the fans’ operation reduces the energy consumption.
  • The Hot Swap system enables maintenance operations during continuous operation of the device. Connecting the fans to the multiswitch strip allows for independent switching off of the serviced fan.
  • Monitoring of air conditioner operating conditions via Ethernet.
  • Double power supply.
  • Automatic activation of the emergency line in case of power failure.

Chilled water

The Chilled Water system features the use of chilled water supplied by an internal or external chiller. In the case of a Free Cooling chiller, the outside air cools the water through a heat exchanger. In this case, the energy consumption is as short as possible. The cooling capacity of the heat exchangers ranges from 12.3 to 37.7 kW

Direct expansion

The heat load absorbed by the refrigerant is released to the outside environment by modular condensing units with a cooling capacity of 4.4 kW to 22.3 kW.

Technical data

Z-SERVER cabinet
Height
42 U (2000 mm)
45 U (2100 mm)
47 U (2200 mm)
Width
600 mm / 800 mm
Depth
1200 mm
Precision air conditioning system
Type Side heat exchanger (Chilled Water or Direct Expansion)
Technology: Chilled Water
Model
BWC-CW1
BWC-CW2
BWC-CW3
The cooling capacity [kW]
22.6
31
37.7
Number of fans
3
5
5
Technology: Direct Expansion
Refrigerant
R410A
Model
BWC-DX1
BWC-DX1
BWC-DX2
BWC-DX2
BWC-DX2
The cooling capacity [kW]
4.5-8.4
11.2-22.3
Number of fans
3
3
5
5
5
Condenser (outdoor unit)
SDX1
SDX2
SDX3
SDX4
SDX5
The cooling capacity [kW]
4.5
8.4
11.2
14
22.3
Power strips 230V
Available functionalities Basic, monitored entry/exit, managed, managed and monitored
Maximum current [A]
16
32
3x16
3x32
Maximum load [kW]
3.6
7.2
11.1
22.1
Available sockets
C13, C19, schuko, UTE
Monitoring of environmental conditions
Measurement temperature, humidity, air flow
Detection smoke, no voltage, spot or line flooding, door opening, movement, vibration
Sygnaling LCD display, status lamp, alarm siren with strobe
Notification trapy SNMP, e-mail, SMS
Fire detection and extinguishing system
Extinguishing substance
Novec 1230

Sales and support

Grzegorz Woźniak

Data center solutions advisor
grzegorz.wozniak@zpas.pl
+48 603 199 629
74 873 54 93

Karina Szramek

Senior sales specialist
karina.szramek@zpas.pl
+48 607 872 856
+48 74 872 01 08

Paweł Kaczmarski

Senior sales specialist
pawel.kaczmarski@zpas.pl
+48 661 926 144
+48 74 872 01 55