Switchgears up to 3200 A

You are here: Start Product catalogue Control cabinets & electric switchgears Switchgears up to 3200 A

Switchgears up to 3200 A


More Views

The SZE3/SGP System Switchgears are designed for distribution of electricity, as well as for control and protection of electrical equipment against short circuits and overloads. They give the user a high level of safety and comfort. The main features of SZE-3 switchgears are modularity and compactness. Also, the cabinets are adapted to the units they hold so that the units can be used fully.
Description Specification Configurator Accessories Connected
Grzegorz Bartusiak bartusiak@zpas.pl +48 74 872 0691 +48 609 449 924


  • - Easy and safe operation.
  • - Easy to modify (reconstruct and expand), easy to replace damaged units and adapt them to changing needs.
  • - Clear spatial and functional division.
  • - Compact design for optimum use of space.
  • - Highly reliable.
  • - Withdrawable units provide high level of safety for personnel and enable quick replacement of supply units without having to shut down the entire switchgear.
  • - Easy service and maintenance.
  • - Withdrawable, mobile (pin) and fixed functional units can be used together in a cabinet.
  • - Possible to use disconnectors with fuses in the form of moving units in a horizontal layout.

As presented, the most frequently used cabinets and functional units can be expanded with other solutions to suit the customer's needs.
Switchgears and controlgears available in the SZE3/SGP system undergo full type testing and meet PN-EN 61439-1 and PN-EN 61439-2 standards, with every single unit being subject to product testing.

Switchgear parameters
Switchgear type SZE3/SGP 3200 A
Rated current In 3200 A
Rated switching voltage Ue 230/400 V
Rated insulation voltage Ui 1000 V
Withstand voltage at 50 Hz mains frequency 2200 V
Rated short-time power frequency withstand voltage U imp 1.2/50 of the main circuit 8000 V
Rated frequency fn 50 Hz
Rated short-time withstand current Icw
main busbars
distribution busbars
N and PE busbars

100 kA, 1 s
100 kA, 1 s
60 kA, 1 s
Rated peak withstand current I pk
main busbars
distribution busbars
N and PE busbars

220 kA
220 kA
132 kA
Protection class IP31 – design I, IP55 – design II
Insulation class I
Busbar layout L1, L2, L3, N, PE
Main phase busbar system Overhead
Mains type TN-C, TN-C-S, TN-S, TT, IT
Design For indoor systems
For outdoor systems
Body dimensions H × W × D [mm]
- incoming feeder
- outgoing feeder with vertical strip disconnectors
- outgoing feeder with horizontal strip disconnectors
- outgoing feeder with moulded-case circuit breakers

2100 × 800 × 600
2100 × 800 × 600
2100 × 1000 × 600
2100 × 1000 × 600

Attribute Value
Catalogue number 3794